66 Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
Appendix A Standard Drive Parameters
[Pr - 0.31] Allocation of Output Signals 10
Range for all digits 0…3, where 0 is Off and 1…6 are digital outputs
Data Size 4 digits
Digit Description Default
0 Reserved 0x0
1 Reserved 0x0
2 Reserved 0x0
3 Reserved 0x0
When Enabled Reserved
Applicable Operating Mode Indexing
Modbus Address 32
[Pr - 0.32] I/O Control Authority
Applicable Operating Mode All
Data Size 2 digits
Digit 0 Modbus Input Function Control
Ultraware Name Modbus Input Function Control
Range Value Description
0x0 Disable
0x1 Enable
Default 0
Digits 1 Modbus Run Function Control
Ultraware Name Modbus Run Function Control
Range Value Description
0x0 Disable
0x1 Enable
Default 0
When Enabled Servo-Off -> Setting
(1)
(1) Refer to Setting Values for Parameters [Pr - 0.22]…[Pr - 0.32] in the table immediately below.
Applicable Operating Mode All
Modbus Address 33
Setting Values for Parameters [Pr - 0.22]
[Pr - 0.32]
Setting Value
(1)
(1) Setting Values are reserved (not available) for [Pr - 0.28] and [Pr - 0.31].
6 5 4 3 2 1 0
Input Channel No. AL #3 AL #2 AL#1 DO#3 DO#2 DO#1 Input Signal
CN1 Pin No. 39 38 37 47,48 43,44 41,42 Off